CO2 Type Fire Extinguisher

In stock

The CO2 Type Fire Extinguisher uses pressurized carbon dioxide gas as its extinguishing agent, making it particularly effective against Class B fires involving flammable liquids and Class C fires involving live electrical equipment, since CO2 leaves no residue and does not conduct electricity. When discharged, the CO2 expands rapidly and displaces oxygen around the fire, effectively smothering the flames by removing one of the three elements required for combustion, while also providing a cooling effect due to the rapid expansion of the gas.

Because CO2 extinguishers leave behind no chemical residue or moisture, they are the preferred choice for use in server rooms, control panels, laboratories, and other sensitive environments where dry chemical powder or water-based extinguishers could cause additional damage to delicate electronic equipment. The extinguisher is typically identifiable by its distinctive horn-shaped nozzle, which helps direct the concentrated stream of gas onto the fire source while minimizing the risk of frostbite to the operator’s hand from the extremely cold discharge. CO2 Type Extinguishers are commonly installed in data centers, electrical switch rooms, laboratories, and areas with sensitive machinery where clean fire suppression without residue is essential.

Description

Advantages

Because CO2 leaves no residue and does not conduct electricity, the CO2 Type Fire Extinguisher is uniquely suited to protecting sensitive electronics from both fire and secondary damage that dry chemical or water-based agents might otherwise cause. The gas rapidly displaces oxygen around the fire while also providing a cooling effect from its expansion, extinguishing flames cleanly.

Its distinctive horn-shaped nozzle directs a concentrated stream precisely onto the fire source, and the absence of chemical residue means server rooms, control panels, and laboratories can resume normal operation quickly after use without extensive cleanup.

CO2 extinguishers are specified wherever a clean, residue-free suppression method is required around sensitive equipment.
  • Server rooms and data centres
  • Electrical switch rooms and control panels
  • Laboratories with sensitive instruments
  • Areas with delicate machinery vulnerable to residue damage
  • Electrical fires where non-conductive agents are required
Data centres, electrical switch rooms, and laboratories install CO2 extinguishers specifically because they need residue-free suppression that will not damage sensitive machinery or electronics. Users should be cautious when discharging CO2 extinguishers in small, enclosed spaces due to the risk of oxygen displacement affecting breathable air, and the extinguisher should be checked periodically for proper pressure retention.